New ICA S & H Strain Gage and Load Cell Analogue Miniature Amplifiers ICA S & H In-Cell Amplifiers New ICA S & H InCell Analogue Strain Gauge and Load Cell Amplifiers
Cost-efficient, analogue signal conditioning
Now with higher performance!

ICA In Cell Strain Gauge Analog Signal Conditioning Amplifiers General Datasheet
 


    Search our site:

The Industrial Stability S & Very High Stability H Strain Gauge or Load Cell Analogue Amplifier are designed to be incorporated directly into strain gauge sensors such as pressure transducers, load cells and torque sensors, the ICA family offers high stability with a wide bandwidth. They do have applications where small size and weight, and low cost, is essential. They are ideal for Reseach and Development applications, as well as being a cost-efficient solution for production.

As well as the S and H versions, an ATEX version is also available.

Industrial Stability ICAS Output Configuration
ICA1S 0.1 - 10.1V
3 wire
ICA2S 0.1 - 5V
3 wire
ICA3S 0 ± 10V
4 wire
ICA4S 4 - 20 mA
3 wire
ICA5S 4 - 20 mA
2 wire
ICA6S ± 10V output
15-24V supply
3 wire
ATEX (Intrinsically Safe)
ICA5A 4 - 20mA
2 wire
Very High Stability ICAH
ICA1H 0.1 - 10.1V
3 wire
ICA2H 0.1 -5V
3 wire
ICA3H 0 ± 10V
4 wire

ICA4H

4 - 20mA
3 wire
ICA6H ± 10V 15-24V
3 wire

 

 

 

 

 

 

 

 

 

 

 

Improvements in the Enhanced ICA Ranges:

Ceslum Technologies for strain gauge and strain gage signal conditioning amplifiers Wider output ranges on ICA1 and ICA2
Ceslum Technologies for strain gauge and strain gage signal conditioning amplifiers Standard excitation of 5V
Ceslum Technologies for strain gauge and strain gage signal conditioning amplifiers Improved operating temperature performance
Ceslum Technologies for strain gauge and strain gage signal conditioning amplifiers User selectable span resistor
Ceslum Technologies for strain gauge and strain gage signal conditioning amplifiers Plated through holes for wire connections
Ceslum Technologies for strain gauge and strain gage signal conditioning amplifiers Standardised mounting hole
Ceslum Technologies for strain gauge and strain gage signal conditioning amplifiers RoHS Compliant
Ceslum Technologies for strain gauge and strain gage signal conditioning amplifiers Reduced standard height of 7.6mm
Ceslum Technologies for strain gauge and strain gage signal conditioning amplifiers Non Interaction between the trimmers makes calibration easier and faster
Ceslum Technologies for strain gauge and strain gage signal conditioning amplifiers ILE Inline Converter Housing now available to house your ICA

...And there are still these Features:

Ceslum Technologies for strain gauge and strain gage signal conditioning amplifiers ICA is mounted at the strain gauge
Ceslum Technologies for strain gauge and strain gage signal conditioning amplifiers Long cables with low signals eliminated
Ceslum Technologies for strain gauge and strain gage signal conditioning amplifiers High level signal transmitted from source
Ceslum Technologies for strain gauge and strain gage signal conditioning amplifiers Plug and go - maintenance free
Ceslum Technologies for strain gauge and strain gage signal conditioning amplifiers Simplified system loop
Ceslum Technologies for strain gauge and strain gage signal conditioning amplifiers Reduced installation costs
Ceslum Technologies for strain gauge and strain gage signal conditioning amplifiers Precalibration of electronics to transducer
      -saves installation time
Ceslum Technologies for strain gauge and strain gage signal conditioning amplifiers Torque, force, load, pressure directly to your system
Ceslum Technologies for strain gauge and strain gage signal conditioning amplifiers SCADA/Controller/Recorder/PLC/PC
Ceslum Technologies for strain gauge and strain gage signal conditioning amplifiers Integrated module
Ceslum Technologies for strain gauge and strain gage signal conditioning amplifiers No remote electronics to mount - or buy!
Ceslum Technologies for strain gauge and strain gage signal conditioning amplifiers Unscreened low cost cable
Ceslum Technologies for strain gauge and strain gage signal conditioning amplifiers No need to protect sensitive signals
Ceslum Technologies for strain gauge and strain gage signal conditioning amplifiers Hardware cost reduction
Ceslum Technologies for strain gauge and strain gage signal conditioning amplifiers Pre-calibrated
Ceslum Technologies for strain gauge and strain gage signal conditioning amplifiers No behind-panel modules - saves space and power
Ceslum Technologies for strain gauge and strain gage signal conditioning amplifiers Reduced stock
      - can be used on ALL types and ranges of strain gauge
output-SUBMINIATURE PACKAGE
Ceslum Technologies for strain gauge and strain gage signal conditioning amplifiers Low unit cost, generous quantity discounts. Contact us for details
Ceslum Technologies for strain gauge and strain gage signal conditioning amplifiers
May be purchased online via our secure OnLine Store -
Ceslum Technologies for strain gauge and strain gage signal conditioning amplifiers Fast delivery - usually ex stock from factory

Download Centre:

General Datasheet
ICA In Cell Strain Gauge Analog Signal Conditioning Amplifiers General Datasheetheet
ICA1 & 2 S & H
ICA1 In Cell Strain Gage Conditioning Amplifier Manual
ICA3 & 6 S & H
ICA2 In Cell Strain Gage Conditioning Amplifier Manual
ICA4 S & H
ICA3 Strain Gage Signal Conditioning Amplifier Manual
ICA5 S & H
ICA4 Strain Gage Signal Conditioning Amplifier Manual

Buy securely OnLine now using

Industrial Stability "S" Versions:

ICA1S 3-wire, 0.1 - 10V DC  £68.75

ICA2S  3-wire, 0.1 - 5V DC  £68.75

 


ICA3S  4-wire, ±10V DC  £68.75


 


ICA4S  3-wire, 4 - 20mA DC  £68.75
 

 


ICA5S, 2-wire, 4 - 20mA DC  £82.75 

 

ICA6S, 3-wire, ± 10V, 15-24V  £82.75 

 

ICA5A , ATEX 2-wire, 4 - 20mA DC  £200.00 

 

 

Very High Stability "H" Versions:

ICA1H 3-wire, 0.1 - 10V DC  £93.00

ICA2H  3-wire, 0.1 - 5V DC  £93.00

 


ICA3H  4-wire, ±10V DC  £93.00


 


ICA4H 3-wire, 4 - 20mA DC  £93.00
 

 


ICA6H  3-wire, ±10V, 15-24VDC supply  £106.50 

 


ILE Inline Converter Housing £56.50

 

*Please note that Signed-For Aimail shipments can take several weeks to arrive

Terms, conditions and policies of sale

 

Please contact us for a Quotation

 

 

New ICA S & H In-cell Strain Gauge, Load Cell, Pressure Sensor and Torque Transducer Amplifier

ICA4H In Cell Amplifer, 4-20mA output strain gage conditioning amplifier, 3 wire, very high stability

ICA3H 0 ± 10VDC output, 4 wire, High Stability strain gauge conditioning amplifier

Scroll down to
Buy OnLine

RoHS Statement

Join Our Email List
Email:  

Go to Celsum Home PageGo to Celsum Main Catalogue PageNews from Celsum TechnologiesSearch Celsum Technologies' Web SiteContact Details and Enquiry FormCelsum Technologies' background informationUseful links to complementary sitesContact Celsum's WebMaster by Email

© 2008 Celsum Technologies Limited
Registered in England & Wales, No 4769781
: VAT Registration No: GB 812 8796 04
Registered Office: The Innovation Centre, De Montfort University, 49 Oxford Street, Leicester LE1 5XY, UK
Page last updated 8 June 2008 : Specifications subject to change without notice : E & OE

Site Meter

Home      Products      News     Search     Contact Us     About Us     Links     WebMaster