Features:

  • RS485 Digital Output – Connect directly to a PC or PLC
  • Male/male, female/male or female/female threads
  • Full Scale Ranges 200 N to 50 kN (50lb to 10,000lb)
  • Static and Dynamic applications
  • Tension and/or Compression
  • Fieldbus Compatibility
  • Shunt Calibration
  • Low deflection
  • Sealed to IP65

The MDLC series has been developed with miniature size and low weight to measure tension and/or compression in static and dynamic applications and to connect directly to digital networks without the need for additional conditioning electronics. All the MDLC needs is a power supply and a suitable communication port.

The MDLC sensing element is a fully temperature-compensated strain gauge bridge equipped with high stability strain gauges to optimise performance at low ranges and frequencies. The strain gauge is connected to an integral DCell digital strain gauge conditioning amplifier (also available separately from Celsum Technologies). The DCell provides an energising voltage to the strain gauge, is fully programmable, has an integral shunt calibration resistor, and has an RS485 digital interface available in a choice of protocols.

Technical Specifications:

Range, Full Scale: Newtons
                Pounds-force(lbf)

200, 500, 1000, 2000, 5000, 10000, 20000, 50000
50, 100, 200, 500, 1000, 2000, 5000, 10000

Over-range:

Without damage:      1.5 x Full Scale
Without destruction: 2.0 x Full Scale

Accuracy:

Non-linearity : ≤±0.25% F.S.
Hysteresis :     ≤ 0.30% F.S.

Temperature Range :

Operating Temp. Range (OTR): -20 to +80°C
Compensated Temp. Range (CTR): 0 to +70 °C
Zero Shift: <±0.005% F.S. / °C
Sensitivity Shift: <±0.005% F.S. / °C

Humidity:

0 – 95% RH Non-condensing

Construction:

17-4PH Stainless Steel

Electrical Characteristics:

Supply Voltage:

5.4 to 18V DC

Current (max)

20 - 40 mA, depending on supply voltage

Power supply ripple

100 mV AC peak-to-peak

Electrical Termination:

Shielded 4-core cable, 2 metres long

Protection:

IP65

 

HIGH STABILITY

INDUSTRIAL STABILITY

Offset Temperature Stability Typ:

1 ppm/°C

5 ppm/°C

Offset Temperature Stability Max:

4 ppm/°C

10 ppm/°C

Gain Temperature Stability Typ:

3 ppm/°C

30 ppm/°C

Gain Temperature Stability Max:

5 ppm/°C

50 ppm/°C

Offset Stability With Time Typ:

0.002% Full Range

0.0035% Full Range

Offset Stability With Time Max:

0.008% Full Range

0.016 % Full Range

Gain Stability with Time Max:

30 ppm of FR/1 st Year

300 ppm of FR/1 st Year

Internal Resolution:

1:16,000,000 (0.0000065%)

1:16,000,000 (0.0000065%)

Resolution at 1Hz 1

1:400,000

1:100,000

Resolution at 10Hz 1

1:120,000

1:40,000

Resolution at 100Hz 1

1:50,000

1:10,000

Resolution at 500Hz 1

1:18,000

1:5,000

RS485 Data Rate:

2,400 to 230,400 baud

1 Update speeds are user-selectable to 1,2,5,10, 20, 50, 60, 100, 300 or 500 samples per second


Wiring Diagram for Several DCell Conditioning Amplifiers

Wiring Diagram for MDLC Miniature Digital Tension-Compression Load Cell Strain Gage Transducer with integral DCell Digital Strain Puck conditioning amplifier

Full Scale Range

TM

TF

DF mm

W

mm

200N to 20kN

M12

M12

16

14

50kN

M16

M16

20

18

 

 

 

 

Dimensional Drawing of MDLC
Please contact us if you need different dimensions, and we will do our best to help

MDLC Miniature Digital Tension / Compression Load Cells
Contact us for more details

 

MDLC Miniature Digital Tension.Compression Loadcell for force measurement

MDLC Miniature Digital Tension/Compression Loadcell with Twin Female Fittings (FF)

MDLC Miniature Digital Tension.Compression Loadcell

MDLC Miniature Digital Tension/Compression Loadcell with Twin Male Fittings (MM)

Join Our Email List
Email:  

Go to Celsum Home PageGo to Celsum Main Catalogue PageNews from Celsum TechnologiesSearch Celsum Technologies' Web SiteContact Details and Enquiry FormCelsum Technologies' background informationUseful links to complementary sitesContact Celsum's WebMaster by Email

© 2008 Celsum Technologies Limited
Registered in England & Wales, No 4769781
: VAT Registration No: GB 812 8796 04
Registered Office: The Innovation Centre, De Montfort University, 49 Oxford Street, Leicester LE1 5XY, UK
Page last updated 8 June 2008 : Specifications subject to change without notice : E & OE

Site Meter

Home      Products      News     Search     Contact Us     About Us     Links     WebMaster