Features:
- RS485 Digital Output – Connect directly to a PC or PLC
- Male/male, female/male or female/female threads
- Full Scale Ranges 200 N to 50 kN (50lb to 10,000lb)
- Static and Dynamic applications
- Tension and/or Compression
- Fieldbus Compatibility
- Shunt Calibration
- Low deflection
- Sealed to IP65
The MDLC series has been developed with miniature size and low weight to measure tension and/or compression in static and dynamic applications and to connect directly to digital networks without the need for additional conditioning electronics. All the MDLC needs is a power supply and a suitable communication port.
The MDLC sensing element is a fully temperature-compensated strain gauge bridge equipped with high stability strain gauges to optimise performance at low ranges and frequencies. The strain gauge is connected to an integral DCell digital strain gauge conditioning amplifier (also available separately from Celsum Technologies). The DCell provides an energising voltage to the strain gauge, is fully programmable, has an integral shunt calibration resistor, and has an RS485 digital interface available in a choice of protocols.
Technical Specifications:
Range, Full Scale: Newtons
Pounds-force(lbf)
|
200, 500, 1000, 2000, 5000, 10000, 20000, 50000
50, 100, 200, 500, 1000, 2000, 5000, 10000
|
Over-range: |
Without damage: 1.5 x Full Scale
Without destruction: 2.0 x Full Scale |
Accuracy: |
Non-linearity : ≤±0.25% F.S.
Hysteresis : ≤ 0.30% F.S. |
Temperature Range : |
Operating Temp. Range (OTR): -20 to +80°C
Compensated Temp. Range (CTR): 0 to +70 °C
Zero Shift: <±0.005% F.S. / °C
Sensitivity Shift: <±0.005% F.S. / °C
|
Humidity: |
0 – 95% RH Non-condensing |
Construction: |
17-4PH Stainless Steel |
Electrical Characteristics: |
Supply Voltage: |
5.4 to 18V DC |
Current (max) |
20 - 40 mA, depending on supply voltage |
Power supply ripple |
100 mV AC peak-to-peak |
Electrical Termination: |
Shielded 4-core cable, 2 metres long |
Protection: |
IP65 |
|
HIGH STABILITY |
INDUSTRIAL STABILITY |
Offset Temperature Stability Typ: |
1 ppm/°C |
5 ppm/°C |
Offset Temperature Stability Max: |
4 ppm/°C |
10 ppm/°C |
Gain Temperature Stability Typ: |
3 ppm/°C |
30 ppm/°C |
Gain Temperature Stability Max: |
5 ppm/°C |
50 ppm/°C |
Offset Stability With Time Typ: |
0.002% Full Range |
0.0035% Full Range |
Offset Stability With Time Max: |
0.008% Full Range |
0.016 % Full Range |
Gain Stability with Time Max: |
30 ppm of FR/1 st Year |
300 ppm of FR/1 st Year |
Internal Resolution: |
1:16,000,000 (0.0000065%) |
1:16,000,000 (0.0000065%) |
Resolution at 1Hz 1 |
1:400,000 |
1:100,000 |
Resolution at 10Hz 1 |
1:120,000 |
1:40,000 |
Resolution at 100Hz 1 |
1:50,000 |
1:10,000 |
Resolution at 500Hz 1 |
1:18,000 |
1:5,000 |
RS485 Data Rate: |
2,400 to 230,400 baud |
1 Update speeds are user-selectable to 1,2,5,10, 20, 50, 60, 100, 300 or 500 samples per second |

Wiring Diagram for Several DCell Conditioning Amplifiers

Full Scale Range |
TM |
TF |
DF mm |
W
mm |
200N to 20kN |
M12 |
M12 |
16 |
14 |
50kN |
M16 |
M16 |
20 |
18 |
Dimensional Drawing of MDLC
Please contact us if you need different dimensions, and we will do our best to help

Contact us for more details
|