TIO
Radio Telemetry Input-Output Module

Download the datasheet for the TSC Strain Gauge to Radio Telemetry ModuleQuantity Discount Price List 

    Search our site:

The TIO is a high performance, very flexible telemetry instrument that provides digital and analogue IO to a radio telemetry system. The nature and combination of the IO signals is determined by a range of plug-in modules, so the user can configure the instrument to suit their application. The TIO can be driven or read from a computer connected to a TCM as well as allowing other Telemetry devices to modify the IO parameters; the TIO has the capability of requesting data from other devices and modifying its outputs accordingly.

Key Features:

Selection of Digital and Analog Inputs & Outputs
Very high stability
Remote power on/off
Voltage free contact retransmission
Operates from 15 - 28V DC power supply
Power consumption in Receive Mode 60mA
Power consumption in Transmit Mode 76mA
Configured & calibrated via PC using TCM module
Supplied with free software toolkit
Electrical isolation gives high immunity
   to electrical storms
Error-free, 2-way radio system
Internal antenna supplied
Minitoring Watch Functions
External antenna can be fitted to increase
    performance
Protocol ASCII XP
Data rate 1 to 10 updates per sec
IP65/NEMA ABS glanded case
Impending power fail detection & shutdown
Low power detection & hold off
Size 150 x 80 x 55mm
Connections via screw & snap terminals
1 year manufacturer's warranty
Two models available:

            868 MHz for the European market
             20mW power, 300 metres (330 yards)
             range, 36 channels
            915 MHz for the USA & Canadian
             markets; 10mW power, 200 metres
             (220 yards) range, 130 channels

Plug-In Modules
The TIO will accept up to 1 Analogue Input, 1 Analogue Output, 1 Digital Input and 1 Digital Output module, each which may be located in any of the four slots.

Digital
Inputs

TIODI1   8 digital inputs for zero voltage contacts or
               2 - 24V voltage signals

Digital Outputs

TIODO1   8 open collector digital outputs.
              Each output can sink up to 20mA,
              Maximum voltage 24VDC

TIODO2   8 normally open relay outputs.
              Rated 20V 1A
              TIO supply voltage must be 18V DC min

Analogue Input

TIOAI1    0-10V and 4-20mA analog input
              10 bit (1 part in 1024) resolution
              Accuracy ±0.06% of Full Scale
              Linearity ±0.06% of Full Scale

Analogue Output

TIOA01    0-10V and 4-20mA analog output
              15 bit (1 part in 32768) resolution
              Accuracy ±0.03% of Full Scale
              Linearity ±0.02% of Full Scale
              Slew Rate: 0.1 - 10V  200ms
              Slew Rate: 10 - 0.1V 1000ms
              Slew Rate:  4 - 20mA  250ms
              Slew Rate: 20 -  4mA  400ms
              Supply required 15VDC minimum
              4-20mA output at 18V supply can
                drive into 500R load


           Download the datasheet for the TSC Strain Gauge to Radio Telemetry ModuleQuantity Discount Price List

 
TIO Radio Telemetry Input - Output Module
The TIO Radio Telemetry Input-Output Module

 

Other Radio Telemetry Instruments are the TDM Hand Held Transceiver and Display Unit, the TLC1 Single Channel Strain Gauge to Radio Telemetry unit. the TCM radio telemetry to serial data converter, the TSC card, the TDU display unit and VisualLINK Rapid Application Development / SCADA software.

Please note: A TCM is required to program the TIO.

Check out the D-Cell cylindrical digital strain gauge amplifiers, the DSC Digital Strain Card, and the ICA and SGA analogue strain gauge amplifiers, too!

 

RoHS Statement

 

 

 

Diagram of TIO layout

Diagram of the TIO circuit board

Join Our Email List
Email:  

Go to Celsum Home PageGo to Celsum Main Catalogue PageNews from Celsum TechnologiesSearch Celsum Technologies' Web SiteContact Details and Enquiry FormCelsum Technologies' background informationUseful links to complementary sitesContact Celsum's WebMaster by Email

© 2008 Celsum Technologies Limited
Registered in England & Wales, No 4769781
: VAT Registration No: GB 812 8796 04
Registered Office: The Innovation Centre, De Montfort University, 49 Oxford Street, Leicester LE1 5XY, UK
Page last updated 8 June 2008 : Specifications subject to change without notice : E & OE

Site Meter

Home      Products      News     Search     Contact Us     About Us     Links     WebMaster